Dredge Lexington Installation
Error message
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Notice: Trying to access array offset on value of type int in element_children() (line 6542 of /home2/hydraul5/public_html/includes/common.inc).
- Deprecated function: The each() function is deprecated. This message will be suppressed on further calls in _menu_load_objects() (line 579 of /home2/hydraul5/public_html/includes/menu.inc).
- Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home2/hydraul5/public_html/includes/common.inc).
Sawyer Systems provided the non-welded piping systems system for this Cutter Head Dredge. The system was pre-engineered and over 75% shop fabricated and shipped to the shipyard.
The field installation included mounting and plumbing between manifold blocks welded into the bulkhead walls and deck steel. The picture on the right is an example of the plumbing feeding through the deck steel to the swing winches mounted above. Once the system was installed, each pipe run was flushed to a specification, pressure tested and certified ready for operation. Our crews continued on-site through commissioning of the equipment to guarantee a successful system.
The pictures below show other examples of the installation. Selecting each picture will expand it to show more detail and give a further description.